title: Lab Module Configuration
slug: ryze/lab-module-configuration
description: Learn how to configure Lab settings and mappings in Medidata Rave's Lab module for handling Central Lab data. This document provides step-by-step instructions for configuring Lab settings in the Lab Administration module and defining Lab Variable Mappings
createdAt: 2023-09-29T10:50:33.228Z
---

Medidata Rave provides a Lab module to handle Central Lab data. Some aspects of the Labs configuration are not available via the ALS and must be configured from Architect.

## Lab Settings

Within Rave Architect, configure the following from the Lab Administration module:

- Standard Units - a Standard Group lists the standard unit for each Analyte in a project
- Reference Labs - reference Lab Ranges will be viewed by sites using Units Only lab forms, or in Outputs
- Alert Labs - alert Lab Ranges will be viewed by end-users when lab values are entered that fall outside of the alert range highs and lows

These settings can be found in ryze at the asset group level in Plugin properties.

## Lab Variable Mappings

Once the Lab settings have been configured in Rave, they can be integrated into the current standard or study. These settings are also found in ryze at the asset group level in Plugin properties.

To define Lab Mappings:

1. Select the asset group and click **Edit properties**.
2. Click **the pencil icon** next to the Medidata Rave version to edit Plugin properties.
3. Scroll down to Lab Variable Mappings and click **Add Lab Variable Mappings group**.
4. Complete the following fields:

- Global Variable OID: enter the OID of a Global Variable defined in the Rave Lab Administration module
- **Note**: A list of Global Variable OIDs is useful when defining Lab Mappings.
- Form OID: select the Form containing the Question from the list
- Field OID: select the Question from the list
- Folder OID: select the Visit containing the Form from the list
- Location Method:
  - Earliest Date: the variable on first form (by date) for the subject will be used
  - Latest Date: the variable on the last form (by date) for the subject will be used Closest in Time to Lab Date: the variable on the form with the closest date to the date of the lab form will be used
  - Closest in Time to Prior to Lab Date: the variable on the form with the closest date to the date of the lab form, as long as that date is earlier than the lab date will be used
  - On Lab Page: the variable on the lab form itself will be used

5\. Click **OK**.